2 - front panel, Power off: the camera head, Triax – Grass Valley EFP1685 Manuel d'utilisation

Page 183

Advertising
background image

Chapter 3 - 1685/1686 Channel Control Unit

183

CCU1686

THOMSON EFP1685/CCU1686

User manual

B1685902AC
September 2000

3.2.2 - Front panel

SHORT CABLE

SYNC. FAIL.

SYNC. OUT

RETURN

VIDEO IN

R OUT

G OUT

B OUT

PAL

ENCODER

STEREO

INTERCOM

VIDEO

4-2-2

ENCODER

fl H

fl S C

fl S C / H

0

G E N
L O C K

R E M O T E

C H R O M A
L E V E L

APCM

O N A I R

1

2

O N L I N E

S T A T U S

MCP

CCU

NUMBER

RCP

1

AUX

C A M

B U S Y

R C P

M C P

O N F A I L

I

O

TRIAX

PRG

ENG

CAM

PROD

CALL

CAM

ENG
CAM

OFF

CCU

POWER

CAMERA

POWER

P O W E R

M A I N S

C A M E R A

C C U

- 3 0 V

+ 1 2 V

T R I A X

O P E N

O V E R
L O A D

C A M

O F F

U N D E R

L O A D

F A I L

+ 3 0 0 V

F A I L

+ 1 2 V

C A M

O N

SHORT CABLE

SYNC. FAIL.

SYNC. OUT

RETURN

VIDEO IN

R OUT

G OUT

B OUT

TRIAX

Indication of short connection ca-
ble between the camera head and
the channel control unit.
With a long cable (> 300 m typeB),
the TelePrompter video is no lon-
ger available on the camera head.

No signal obtained from channel V
indication.
This may be due to:

power off: the camera head,

disconnection of the camera
head

↔ channel control unit in-

terconnection cable.

Test Point for sync signal extracted
from V video (V p/p = 9 V Zout =
300 0hms).

Test Point for outside video signal
applied to the back of the channel
control unit (Zout = 75 Ohms).

R, G, B video signal Test Points,
non-synchronized demodulated
(V p/p = 0.7 V/75 Ohms).

Ground test point

Advertising