Connecting the buffered outputs, Connecting the transducer – Rockwell Automation 1440-DYN02-01RJ XM Dynamic Measurement Module Manuel d'utilisation

Page 34

Advertising
background image

34

Publication ICM-UM002F-EN-E - March 2013

Chapter 2 Installing the XM Dynamic Measurement Module

Connecting the Buffered Outputs

The Dynamic Measurement module provides buffered outputs of all
transducer input signals. The buffered output connections may be used to
connect the module to portable data collectors or other online systems.

Figure 2.11

shows the buffered output connections for the module.

Figure 2.11 Buffered Output Connections

Connecting the Transducer

The module can accept input from any Allen-Bradley non-contact eddy
current probe, a standard IEPE accelerometer, a velocity transducer, AC
voltage output, or a DC voltage output measurement device.

Connecting an IEPE Accelerometer

The following figures show the wiring of an IEPE accelerometer to the
terminal base unit.

ATTENTION

You may ground the cable shield at either end of the cable. Do
not ground the shield at both ends. Recommended practice is to
ground the cable shield at the terminal base and not at the
transducer. Any convenient Functional Earth terminal may be
used. See

Terminal Block Assignments on page 28

.

IMPORTANT

Make certain the

Power parameter is set to IEPE so power is

provided to the transducer.

See Configure the Channel

Properties on page 64

for details.