Transducer Object

(Class ID 328

H

)

The Transducer Object models a transducer.

Class Attributes

The Transducer Object provides no class attributes.

Instances

There are 3 instances of this object.

Instance Attributes

Table B.48 Band Measurement Object Instances

Instance

Descriptions

1

Vibration Channel 0

2

Vibration Channel 1

3

Tachometer Channel

Table B.49 Transducer Object Instance Attributes

Attr ID

Access

Rule

Name

Data Type

Description

Semantics

3

Get

DC Bias

REAL

The measured average DC
bias of the transducer
signal in volts.

Volts

4

Get

Status

BOOL

Indicates whether a
transducer fault exists
(the measured

DC Bias is

outside the range
specified by

Fault High

and

Low).

0 = No fault
1 = A transducer fault exists

5

Get/Set

Sensitivity
Value

REAL

Value of the sensitivity of
the transducer in
millivolts per

Sensitivity

Units.

This value must be +/- 15% of
the

Nominal Sensitivity

value.