139

CIP Objects

Appendix B

Services

(1)

Attributes can only be set while the device is in Program Mode. See the description of the Device Mode Object
for more information.

12

Get

Data Format

USINT

The format of the
spectrum data.

0 = Complex data

13

Get

Average Type

USINT

The type of averaging
performed.

0 = Asynchronous (spectrum)
1 = Synchronous (waveform)

Determined by the

Synchronous attribute of the
Channel Object.

When set to Asynchronous,
consecutive spectrum
measurements are averaged
together to produce the

Spectrum data.

When set to synchronous,
synchronized waveforms are
averaged together to produce
the

Waveform data, and the

Spectrum data is produced
from the averaged waveform. A
trigger source from a
tachometer, for example, is
required to obtain the
synchronized waveforms.

14

Get/Set

Number of
Averages

UINT

The number of individual
data sets to be
incorporated into the
average calculation.

0 = Invalid
1 = No averaging
> 1 = Averaging

Table B.38 Spectrum Waveform Measurement Object Instance Attributes

Attr ID

Access

Rule

Name

Data Type

Description

Semantics

Table B.39 Spectrum Waveform Measurement Object Services

Service

Code

Class/Instance Usage

Name

Description

0E

h

Instance

Get_Attribute_Single

Returns a single attribute.

10

h

Instance

Set_Attribute_Single

Sets a single attribute.

(1)

4B

h

Instance

Get_Spectrum_Chunk

Upload a portion of the
current Spectrum data.

4C

h

Instance

Get_Waveform_Chunk

Upload a portion of the
current Waveform data.