Rockwell Automation 1440-DYN02-01RJ XM Dynamic Measurement Module Manuel d'utilisation

Page 138

Advertising
background image

138

Publication ICM-UM002F-EN-E - March 2013

Appendix B CIP Objects

6

Get/Set

FMAX

REAL

The maximum frequency
or order of the spectrum
data.

0...20000 Hz if

Domain = 0.

There are several predetermined
FMAX settings for which
spectrum data can be produced.
If you select an unsupported
value, then the next greater
supported FMAX value will be
used for the spectrum data.

4...40 Orders if

Domain = 1.The

Number of Lines value must
be evenly divisible by the FMAX
value or an Invalid Device
Configuration error will be
returned during the Device
Mode Object Start and Save
services.

7

Get/Set

Number of
Spectrum Lines

UDINT

Number of lines or bins in
the spectrum data.

100, 200, 400, or 800

8

Get/Set

Window Type

USINT

The window function to
be applied to the
waveform data prior to
computing the spectrum.

0 = Rectangular
1 = Hamming
2 = Hanning
3 = Flat Top
4 = Kaiser Bessel

9

Get/Set

Period

REAL

The period of the
waveform.

Seconds if

Domain = 0.

Cycles if

Domain = 1.

10

Get

Number of
Waveform
Points

UDINT

Number of points in the
waveform data.

256, 512, 1024, or 2048

11

Get

Overlap

USINT

The percent overlap
applied to the waveform
data sets used for
calculating the spectrum.

Only 0% supported.

Table B.38 Spectrum Waveform Measurement Object Instance Attributes