INSTALLATION

A4.5

A4.5

CLASSIC® 300D & 300G

PRE-OPERATION SERVICE

READ the engine operating and maintenance

instructions supplied with this machine.

------------------------------------------------------------------------

OIL

This unit is supplied from the factory with the engine

crankcase filled with a high quality SAE 10W/30 oil.

This oil should be acceptable for most typical ambient

temperatures. Consult the engine operation manual

for specific engine manufacturerʼs recommendations.

Upon receipt of the welder, check the engine dipstick to

be sure the oil is at the “full” mark. DO NOT overfill.

FUEL

Fill the fuel tank with the grade of fuel recommended in

the Engine Operatorʼs manual. Make sure the fuel

valve on the water separator is in the open position.

COOLING SYSTEM

The radiator has been filled at the factory with a 50-50

mixture of ethylene glycol antifreeze and water. Check

the radiator level and add a 50-50 solution as needed

(see engine manual or antifreeze container for alter-

nate antifreeze recommendations).

CAUTION

2. Proper support of, and attachment to, the base of

the welding equipment so there will be no undue

stress to the framework.

3. Proper placement of the equipment on the trailer to

ensure stability side to side and front to back when

being moved and when standing by itself while

being operated or serviced.

4. Typical conditions of use, i.e., travel speed, rough-

ness of surface on which the trailer will be operat-

ed; environmental conditions, likely maintenance.

5. Conformance with federal, state and local laws. (1)

(1) Consult your federal, state and local laws regarding specific

requirements for use on public highways.

POLARITY CONTROL AND CABLE SIZES

With the engine off, route the electrode and work

cables through the strain relief bracket on the base and

connect to the studs located below the fuel tank mount-

ing rail. (See size recommendations below.) For pos-

itive polarity, connect the electrode cable to the termi-

nal marked “+”. For Negative polarity, connect the

electrode cable to the “-” stud. These connections

should be checked periodically and tightened if neces-

sary.

When welding at a considerable distance from the

welder, be sure you use ample sized welding cables.

RECOMMENDED COPPER CABLE SIZES

Cables Sizes for Combined Length

of Electrode Plus Work Cable

Amps

Duty Cycle Up to 200ft.(61m) 200 to 250ft.

(61 to 76m)

250

100%

1

1/0

300

60%

1/0

2/0

VEHICLE MOUNTING

Improperly mounted concentrated loads may

cause unstable vehicle handling and tires or other

components to fail.

• Only transport this Equipment on serviceable

vehicles which are rated and designed for such

loads.

• Distribute, balance and secure loads so vehicle

is stable under conditions of use.

• Do not exceed maximum rated loads for compo-

nents such as suspension, axles and tires.

• Use appropriate nuts bolts and lockwashers to

attach the equipment base to the metal bed or

frame of vehicle.

• Follow vehicle manufacturerʼs instructions.

------------------------------------------------------------------------

WARNING

• Stop engine while fueling.
• Do not smoke when fueling.
• Keep sparks and flame away

from tank.

• Do not leave unattended while

fueling.

• Wipe up spilled fuel and allow

fumes to clear before starting
engine.

• Do not overfill tank, fuel expan-

sion may cause overflow.

DIESEL FUEL ONLY-Low sulphur

fuel or ultra low sulphur fuel in U.S.A. and Canada.

------------------------------------------------------------------------

WARNING