Troubleshooting and repair – Lincoln Electric CLASSIC SVM194-A Manuel d'utilisation

Page 188

Advertising
background image

TROUBLESHOOTING AND REPAIR

F-66

F-66

CLASSIC® 300D & 300G

ALTERNATOR ROTOR REMOVAL

AND REPLACEMENT PROCEDURE (continued)

FIGURE F.6 – ROTOR REMOVAL

STATOR

FRAME

NUT

SLEEVE

COLLAR

"BENT"

WASHER

BRUSH

HOLDER

ASSEMBLY

See Figure F.6 for steps 6 - 8.
6. With the 7/16" wrench, remove the two bolts,

nuts and washers mounting the brush holder

assembly to the stator frame.

7. Bend the flat washer away from the rotor lock-

ing nut.

8. With the 1-5/8" socket wrench, remove the

rotor locking nut, washer and sleeve collar.

NOTE: The sleeve collar will have to be

removed with a gear puller. Be careful

not to damage the rotor slip ring assem-

bly. Remove the rotor by pulling it free of

the generator shaft.

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising