Series, Coil short circuit test, Troubleshooting and repair – Lincoln Electric CLASSIC SVM194-A Manuel d'utilisation

Page 179: Series coil short circuit test procedure, Warning

Advertising
background image

Service and repair should be performed only by Lincoln Electric factory trained personnel.

Unauthorized repairs performed on this equipment may result in danger to the technician

or machine operator and will invalidate your factory warranty. For your safety and to avoid

electrical shock, please observe all safety notes and precautions detailed throughout this

manual.
If for any reason you do not understand the test procedures or are unable to perform the

test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-

bleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

This test checks the short circuit output of the welding generator at each current range

tap. This test should be done if the output is considerably higher than indicated on the

current controls, or if there appears to be too little difference between the output of adja-

cent range switch positions.
CAUTION: Very high loads will be applied to the generator during these tests.

Loads higher than 250 amps must only be applied long enough to get

stable meter readings. Severe damage may result if a high load is

applied for more than a minute or two.

MATERIALS NEEDED

Load bank, preferably with a shorting contactor.

Length of heavy weld cable about 10 feet long (if load bank has no shorting contactor)

Ammeter, able to accurately read about 450 Amps.

Misc. hand tools

Voltmeter or Multimeter Tachometer or Multimeter that can read frequency

SERIES COIL SHORT CIRCUIT TEST PROCEDURE

TROUBLESHOOTING AND REPAIR

F-57

F-57

CLASSIC® 300D & 300G

WARNING

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master