INSTALLATION

A3.4

A3.4

CLASSIC® 300D & 300G

PRE-OPERATION INSTALLATION

EXHAUST SPARK ARRESTER

Some federal, state or local laws may require that engines be

equipped with exhaust spark arresters when they are oper-

ated in certain locations where unarrested sparks may pre-

sent a fire hazard. The standard muffler included with this

welder does not qualify as a spark arrester. When required

by local regulations, a suitable spark arrester must be

installed and properly maintained.

Use of an incorrect arrester may lead to engine damage or

performance loss. Contact the engine manufacturer for spe-

cific recommendations.

--------------------------------------------------------------------------------

LOCATION/VENTILATION

Always operate the welder with the doors closed. Leaving the

doors open changes the designed air flow and may cause

overheating.

The welder should be located to provide an unrestricted flow of

clean, cool air. Also, locate the welder so that engine exhaust

fumes are properly vented to an outside area.

ANGLE OF OPERATION

Engines are designed to run in the level condition which is

where the optimum performance is achieved. The maximum

angle of continuous operation is 20 degrees in all directions, 30

degrees Intermittent (less than 10 minutes continuous) in all

directions.

If the engine is to be operated at an angle, provisions must be

made for checking and maintaining the oil level at the normal

(FULL) oil capacity in the crankcase.

When operating the welder at an angle, the effective fuel

capacity will be slightly less than the amount specified.

MACHINE GROUNDING

According to the United States National Electrical Code, the

frame of this portable generator is not required to be grounded

and is permitted to serve as the grounding means for cord con-

nected equipment plugged into its receptacle.

Some state, local, or other codes or unusual operating circum-

stances may require the machine frame to be grounded. It is

recommended that you determine the extent to which such

requirements may apply to your particular situation and follow

them explicitly. A machine grounding stud marked with the sym-

bol is provided on the welding generator frame foot. In gen-

eral, if the machine is to be grounded, it should be connected

with a #8 or larger copper wire to a solid earth ground such as

a metal water pipe going into the ground for at least ten feet

and having no insulated joints, or to the metal framework of a

building which has been effectively grounded. The U.S.

National Code lists a number of alternate means of grounding

electrical equipment.

LIFT BAIL

A lift bail is provided for lifting with a hoist.

Do not attempt to use this equipment until you have

thoroughly read the engine manufacturerʼs manual sup-

plied with your welder. It includes important safety pre-

cautions, detailed engine starting, operating and mainte-

nance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or elec-

trode with skin or wet clothing.

• Insulate yourself from work and ground

• Always wear dry insulating gloves.

--------------------------------------------------------------------------------

ENGINE EXHAUST can kill.

• Use in open, well ventilated areas or vent

exhaust outside.

--------------------------------------------------------------------------------

MOVING PARTS can injure.

• Do not operate with doors open or guards

off.

• Stop engine before servicing.

• Keep away from moving parts.

--------------------------------------------------------------------------------

See additional warning information at the front

of this operatorʼs manual.

-----------------------------------------------------------------

WARNING

CAUTION

DO NOT MOUNT OVER COMBUSTIBLE SURFACES.

Where there is a combustible surface directly under sta-

tionary or fixed electrical equipment, the surface shall be

covered with a steel plate at least .06”(1.6mm) thick,

which shall extend not more than 5.90”(150mm) beyond

the equipment on all side.

--------------------------------------------------------------------------------

CAUTION

• Lift only with equipment of ade-

quate lifting capacity.

• Be sure machine is stable when

lifting.

• Do not lift this machine using

lift bale if it is equipped with a

heavy accessory such as trailer

or gas cylinder.

FALLING

• Do not lift machine if lift bale is

EQUIPMENT can damaged.

cause injury. • Do not operate machine while

suspended from lift bale.

------------------------------------------------------------------------

WARNING