B2.4

B2.4

CLASSIC® 300D & 300G

AUXILIARY POWER

If a GFCI receptacle is tripped, See the MAINTE-

NANCE section for detailed information on testing and

resetting the GFCI receptacle.

The AC auxiliary power, supplied as a standard, has a

rating of 3.0 KVA of 115/230 VAC (60 hertz).

With the 3.0 KVA, 115/230 VAC auxiliary power, one

115V GFCI and one 230V duplex, grounding type

receptacles are provided. The circuit is protected with

circuit breakers.

The rating of 3.0 KVA permits a maximum continuous

current of 13 amps to be drawn from the 230 volt

duplex receptacle. Or a total of 20 amps can be drawn

from the 115 volt GFCI receptacle. The total combined

load of all receptacles is not to exceed 3.0 KVA.

An optional power plug kit is available. When this kit is

specified, the customer is supplied with a plug for each

receptacle.

IDLER OPERATION

Start the engine with the “Idler” switch in the “High”

position. Allow it to run at high idle speed for several

minutes to warm the engine. See Specifications for

operating speeds.

The idler is controlled by the “Idler” toggle switch on the

welder control panel. The switch has two positions as

follows:

1. In the “High” position, the idler solenoid deac-

tivates, and the engine goes to high idle speed. The

speed is controlled by the governor.

2. In the “Auto” / position, the idler oper-

ates as follows:

a. When welding or drawing power for lights or tools

(approximately 100 watts minimum) from the

receptacles, the idler solenoid deactivates and the

engine operates at high idle speed.

b. When welding ceases or the power load is turned

off, a preset time delay of about 15 seconds

starts. This time delay cannot be adjusted.

c. If the welding or power load is not re-started

before the end of the time delay, the idler solenoid

activates and reduces the engine to low idle

speed.

CLASSIC® 300D PERKINS WITH PERKINS 104-22 DIESEL ENGINE

TYPICAL FUEL CONSUMPTION DATA

Low Idle (1400 RPM)-No Load @ 45 Volts

High Idle (1800 RPM)-No Load @ 96.6 Volts

3000 Watts

250 Amps @ 30 Volts

300 Amps @ 32 Volts

0.28 gal/hr ( 1.06 ltrs/hr)
0.42 gal/hr ( 1.59 ltrs/hr)

0.59 gal/hr ( 2.23 ltrs/hr)

1.03 gal/hr ( 3.90 ltrs/hr)

1.37 gal/hr ( 5.19 ltrs/hr)