Troubleshooting and repair, Flashing voltage test procedure (continued) – Lincoln Electric CLASSIC SVM194-A Manuel d'utilisation

Page 158

Advertising
background image

FLASHING VOLTAGE TEST PROCEDURE (continued)

PROCEDURE

1. Remove the cover from the exciter / auxiliary

power alternator.

2. Connect the volt meter probes to the brush ter-

minals. See the wiring diagram.

3. Remove one of the AC input leads from the field

bridge rectifier.

4. Set the idle switch to "HIGH" and the

RUN/STOP switch to "RUN", and start the

engine.

NOTE: The meter should read about 4 to 6 VDC. If

this voltage reading is correct, the test is

complete. If the voltage measures zero or

significantly lower than specified check for

the following:

• An open flashing diode.
• A poor connection in the flashing circuit.
• Polarity of the main generator may be

reversed.

• The rotor winding maybe shorted,
• The field bridge rectifier may be shorted.

5. Reconnect the AC lead to the Field Bridge.
6. With the engine running at High speed, the nor-

mal rotor voltage is 123 to 133VDC.

TROUBLESHOOTING AND REPAIR

F-36

F-36

CLASSIC® 300D & 300G