OUTPUT PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,

contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.

Call 1-888-935-3877.

CAUTION

The weld output is considerably

less than indicated on the dials

or varies abnormally. Auxiliary

output appears normal.

(Continued)

N/A

Perform the Shunt Field Coil

Resistance and Ground

Test.
Check the Generator brush

rocker position; perform the

Rocker Adjustment

Procedure if necessary.

The weld output is considerably

higher than indicated on the

dials. Auxiliary voltage appears

normal.

If a remote current control is

being used, try switching to

local control. The remote

current control may be faulty.

The engine RPM may be too

high; perform the Engine RPM

Adjustment Test.
There may be a short circuit in

the series field coils. Perform

the Weld Circuit Ground and

Short Circuit Test and Series

Coil Short Circuit Test.
Perform the Exciter Rotor

Resistance and Ground Test.
Perform the Shunt Field Coil

Resistance and Ground Test.
Verify that the rocker is

positioned correctly, according

to the factory drill mark.

Perform the Rocker

Adjustment Procedure if

necessary.

TROUBLESHOOTING AND REPAIR

F-8

F-8

CLASSIC® 300D & 300G

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising