Engine rpm, Adjustment test, Engine – Lincoln Electric CLASSIC SVM194-A Manuel d'utilisation

Page 153: Rpm adjustment test, Troubleshooting and repair, Engine rpm adjustment test procedure, Warning

Advertising
background image

Service and repair should be performed only by Lincoln Electric factory trained personnel.

Unauthorized repairs performed on this equipment may result in danger to the technician

or machine operator and will invalidate your factory warranty. For your safety and to avoid

electrical shock, please observe all safety notes and precautions detailed throughout this

manual.
If for any reason you do not understand the test procedures or are unable to perform the

test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-

bleshooting assistance before you proceed. Call 1-888-935-3877.

TEST DESCRIPTION

This test will determine if the engine is operating at the correct RPM, for both high and low

idle positions.

MATERIALS NEEDED

Miscellaneous hand tools

Strobe tachometer

Frequency counter or Multimeter with frequency counter function

Bright colored marking pencil or marker

Note: The engine RPM on the Classic® 300G and 300D with the Kubota engine is not

adjustable. The electronic modules on these machines maintain RPM based on

internal programming and the position of the RPM adjustment potentiometer or

"Custom Arc" control. RPM should still be checked to determine if these sys-

tems are functioning correctly.

ENGINE RPM ADJUSTMENT TEST PROCEDURE

TROUBLESHOOTING AND REPAIR

F-31

F-31

CLASSIC® 300D & 300G

WARNING

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Advertising