TROUBLESHOOTING AND REPAIR

F-59

F-59

CLASSIC® 300D & 300G

This is the typical auxiliary output

voltage generated from a properly

operating machine. Note that each

vertical division represents 50 volts

and that each horizontal division rep-

resents 5 milliseconds in time.

Note: Scope probes connected at

machine 115VAC receptacle.

SCOPE SETTINGS

Volts/Div.....................50V/Div.

Horizontal Sweep.....5 ms/Div.

Coupling.............................DC

Trigger.........................Internal

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)

HIGH IDLE – NO LOAD – FINE CURRENT CONTROL RHEOSTAT AT MAXIMUM

CH1

0 volts

5 ms

50 volts

16.6 ms

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Section

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC

Return

to

Master

TOC