OPERATION

B5.3

B5.3

CLASSIC® 300D & 300G

• When hauling the welder between job sites, close the

fuel feed valve beneath the fuel tank.

• If the fuel supply is cut off or runs out while the fuel

pump is operating, air may be entrapped in the fuel

distribution system. If this happens, bleeding of the

fuel system may be necessary. Refer to the instruc-

tions in the MAINTENANCE section of this manual.

REFER TO THE ENGINE

Operation and maintenance manual for additional

information on the engine supplied with this welder.

WELDER OPERATION

DUTY CYCLE

The NEMA output rating of the Classic® 300G is 300

amperes at 32 arc volts on a 60% duty cycle (consult

Specifications in this manual for alternate ratings).

Duty cycle is based on a ten minute period; thus, the

welder can be loaded at rated output for six minutes

out of every ten minute period.

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or

electrode with skin or wet clothing.

• Insulate yourself from work and ground.

FUMES & GASES can be dangerous.

• Keep your head out of the fumes.

• Use ventilation or exhaust to remove

fumes from breathing zone.

WELDING SPARKS can cause fire or

explosion.

• Keep flammable material away.

ARC RAYS can burn.

• Wear eye, ear, and body protection.

WARNING

Air Cleaner - Heavy duty two stage dry type.

Muffler-A Muffler and stainless steel exhaust outlet

elbow are standard.
Engine Hour Meter - A meter to record hours of opera-

tion.

Engine Protection - The system shuts the engine

down in the event of sudden low oil pressure or high

coolant temperature. A warning light on the control

panel will indicate such a fault. To reset the engine for

restarting, turn the ignition switch off then on.

High Idle RPM (OCV) Adjustment- A potentiometer is

mounted on the output rail that allows the operator to

adjust the high idle engine speed between 1700 and

1800 RPMʼS in 20 RPM increments. This is to allow fur-

ther adjustment of the OCV. Total OCV adjustment

range is about 10 Volts.

STARTING THE CLASSIC® 300G GM 3.0L

GASOLINE ENGINE

1. Turn the “IDLER” switch to “HIGH”.(Optional )

2. Turn the “IGNITION” switch to “ON”.

3. Press the Start button. When the engine starts run-

ning, release button. If the engine fails to start in 20

seconds, wait 30 seconds and repeat the above pro-

cedure.

4. Observe the oil pressure. If no pressure shows with-

in 30 seconds, stop the engine and consult the

engine operating manual. To stop the engine, turn

the “IGNITION” switch to “OFF”.

5. Allow the engine to run at high idle speed for sev-

eral minutes to warm up. If idle control switch is left

in “Auto” position, engine will run at 1600 RPM until

engine coolant temperature reaches 130 F.

Under NO conditions should ether or other starting

fluids be used!

-------------------------------------------------------------------------

STOPPING THE ENGINE

• Turn the “IGNITION” switch to “OFF”

• At the end of each dayʼs welding, check the crankcase

oil level, drain accumulated dirt and water from the

sediment bowl under the fuel tank and refill the fuel

tank to minimize moisture condensation in the tank.

Also, running out of fuel tends to draw dirt into the fuel

system.