SHUNT FIELD CIRCUIT VOLTAGE TEST PROCEDURE (continued)

PROCEDURE

1. Turn the engine off.
2. Open either or both of the side doors.
NOTE: Secure the doors in the open position

using the door restraint system. If the

machine does not have a door restraint

system, remove the doors or securely

restrain them to prevent them from falling

closed.

3. Place the field rheostat in the maximum posi-

tion.

4. Place the remote/local switch in the local posi-

tion.

5. Place the idle switch in the high idle position,

start the engine and allow it to stabilize at high

idle RPM.

6. Locate the J5 Molex connector located in the

harness close to the generator lead block.

7. Test for DC voltage between the brown and

blue wires, pins #3 and #5. The voltage should

be between 123 and 133 VDC.

8. If the measured voltage is normal, but there is

still no usable output from the welding genera-

tor, perform the Shunt Field Coil Resistance

and Ground Test.

9. If the correct voltage is not present at the J5

harness plug, check for voltage at the positive

and negative terminals of the field bridge rectifi-

er. See Wiring Diagram.

10. If 123 to 133 VDC is present at the field bridge

rectifier, check the wiring and connections

between the rectifier, the rheostat, the

remote/local switch, and the J5 Molex connec-

tor. Check the rheostat and the remote/local

switch for proper operation. See Wiring

Diagram.

TROUBLESHOOTING AND REPAIR

F-48

F-48

CLASSIC® 300D & 300G