OPERATION

B1.4

B1.4

CLASSIC® 300D & 300G

AUXILIARY POWER

The AC auxiliary power, supplied as a standard, has a

rating of 3.0 kVA of 115/230 VAC (60 hertz).

With the 3.0 kVA, 115/230 VAC auxiliary power, one

115V duplex and one 230V duplex, grounding type

receptacle are provided. The circuit is protected with

circuit breakers.

The rating of 3.0 kVA permits a maximum continuous

current of 13 amps to be drawn from the 230 volt

duplex receptacle. Or a total of 26 amps can be drawn

from the 115 volt duplex receptacle. The 115 volt

duplex receptacle has a configuration which permits 20

amps to be drawn from either half. The total combined

load of all receptacles is not to exceed 3.0 kVA.

An optional power plug kit is available. When this kit is

specified, the customer is supplied with a plug for each

receptacle.