CONCENTRIC VENT INSTALLATION

This water heater is certified for concentric venting with concentric

vent kit #9006328005. Follow instructions below for proper

installations.

Table 8 – KIT COMPONENTS

Field supplied pipe and fittings are required to complete the

installation.

This concentric vent termination kit may be used with 3 inch diameter

pipe systems.

SAFETY CONSIDERATIONS

Installing and servicing water heating equipment can be hazardous

due to gas and electrical components. Installation and service of

the concentric vent termination requires ability equivalent to that of

a qualified installer or qualified service technician, see Page 7. All

precautions in the literature, on tags, and labels attached to the unit

must be observed.

Follow all safety codes. Wear safety glasses and work gloves.

Figure: 24

Figure: 25

* Dimension 21 1/8 in. may be lengthened to 60 in. maximum.

Dimension 21 1/8 in. may also be shortened by cutting the

pipes, provided in the kit, to 12 in. minimum.

** Dimension 39 will change accordingly as dimension

21 1/8 in. is lengthened or shortened.

Do not use field-supplied couplings to extend pipes. Airflow restriction

will occur and the heater pressure switch may cause intermittent

operation.

INSTALLATION VERTICAL ROOF TERMINATION

1. Determine best location for termination kit.

NOTE: Roof termination is preferred since it is less

susceptible to damage, has reduced chances to intake contaminants,

and less visible vent vapors.

2. Cut 1 hole (5 in. diameter)

3. Partially assemble concentric vent termination kit.

a) Cement Y concentric fitting to larger diameter kit

pipe, see Figure 24.

b) Cement rain cap to smaller diameter kit pipe, see Figure 26.

Figure: 26

NOTE: Instead of cementing the smaller pipe to the rain cap, a

field-supplied stainless steel screw may be used to secure the

2 components together when field disassembly is desired for

cleaning, see Figure 26.

When using alternate screw method, drill clearance hole in rain

cap and pilot hole in vent pipe for screw size being used. Failure

to drill adequate holes may cause cracking of PVC components,

allowing combustion products to be recirculated. Failure to follow

this warning could result in personal injury or death.

Do not operate the heater with rain cap removed or recirculation

of combustion products may occur. Water may also collect inside

larger combustion-air pipe and flow to the burner enclosure.

Failure to follow this warning could result in product damage or

improper operation, personal injury or death.

4. Install Y concentric fitting and pipe assembly through

structure’s hole and field supplied roof boot/flashing.

Figure: 27