Troubleshooting chart, Fvir system operational checklist – John Wood Atmospheric Gas (ENERGY STAR) - NEW Manuel d'utilisation

Page 28

Advertising
background image

28

TROUBLESHOOTING CHART

PROBLEM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

BURNER WILL NOT IGNITE

1. Pilot will not light

2. Thermostat set too low
3. No

gas

4. Dirt in the gas lines
5. Pilot line clogged
6. Main burner line clogged
7. Non-functioning gas control valve/thermo-

stat

8. Heater installed in a confined area
9. Flue Damper not functioning

1. See PILOT WILL NOT LIGHT OR REMAIN

LIT

2. Turn temp. dial to desired temperature
3. Check with gas utility company
4. Notify utility-install trap in gas line
5. Clean, locate source and correct
6. Clean, locate source and correct
7. Replace gas control valve/thermostat

8. Provide fresh air ventilation
9. Cycle power to the water heater off and on. If

problem persists replace the flue damper

PILOT WILL NOT LIGHT OR

REMAIN LIT

1. Non-functioning Pilot\Igniter-Flame Sensor

2. The thermal switch tripped

3. Igniter wire connection loose
4. Air in gas line
5. Low gas pressure
6. No

gas

7. Dirt in gas lines
8. Cold

drafts

9. Thermostat ECO switch open
10. Pilot line or orifice clogged
11. Air for combustion obstructed

12. FV Senor Lockout
13. Flue Damper not functioning

1. See Status Light Code Troubleshooting Table

section

2. See Pilot Light Troubleshooting Flowchart

section

3. Seat connector firmly in socket
4. Bleed the air from the gas line
5. Check with gas utility company
6. Check with gas utility company
7. Notify utility-install dirt trap in gas line
8. Locate source and correct
9. Replace

thermostat

10. Clean, locate source and correct
11. See maintenance section for inspection and

cleaning of flame trap.

12. Contact a qualified person to reset the sensor
13. Cycle power to the water heater off and on. If

problem persists replace the flue damper

BURNER FLAME YELLOW-

LAZY

1. Insufficient secondary air
2. Low gas pressure
3. Flue

clogged

4. Flue damper partially open

5. Main burner line clogged
6. Heater installed in a confined area
7. Obstruction in main burner orifice

1. Provide ventilation to water heater
2. Check with gas utility company
3. Clean, locate source and correct
4. Cycle gas control valve/thermostat OFF then

ON. If problem persists replace damper

5. Clean, locate source and correct
6. Proper fresh air ventilation
7. Clean or replace orifice

HIGH OPERATION COSTS

1. Thermostat set too high
2. Sediment or lime in tank
3. Water heater too small for job
4. Wrong piping connections
5. Leaking

faucets

6. Gas

leaks

7. Wasted hot water
8. Long runs of exposed piping
9. Hot water piping in exposed wall
10. Flue Damper seal not functioning

1. Set temperature dial to lower setting
2. Drain/flush-provide water treatment if needed
3. Install adequate heater
4. Correct piping-dip tube must be in cold inlet
5. Repair

faucets

6. Check with utility-repair at once
7. Advise

customer

8. Insulate

piping

9. Insulate

piping

10. Replace the flue damper

FVIR System Operational Checklist

1. Manifold gasket properly sealed.
2. Viewport not damaged or cracked.
3. Flame-arrestor free of debris and undamaged.
4. Two piece wire connector properly installed.

5. No leaks at pilot and manifold connection.
6. Manifold door screws securely tightened.
7. Depress the button on the thermal switch