ELECTRICAL CONNECTIONS/WIRING DIAGRAM

Electrical Connections

Before plugging in the water heater, always make sure:

The Voltage and frequency correspond to that specified on the
water heater.

The electrical outlet has the proper overload fuse or breaker
protection.

Water heater to be located within 6 feet of 120VAC outlet.

Unit is to connect to a 120VAC electrical supply outlet
(extension cord is not allowed).

The water heater and the outlet are properly grounded.

Installed in accordance with CSA C22.1-current edition
(Canadian Electrical Code) and all local/provincial codes.

Completely fill the tank with water and check all connections for
leaks. Open the nearest hot water faucet and let it run for three
(3) minutes to purge the water lines of air and sediment and to
ensure complete filling of the tank. The Electrical power may then
be turned on. Verify proper operation after servicing.

DAMPER

FLAME SENSOR\IGNITER

GAS CONTROL VALVE\THERMOSTAT

4 3 2 1

3 2 1

6 5 4

FV SENSOR

TEMPERATURE
CUT-OFF SWITCH

FLUE DAMPER

TRANSFORMER

1 2 3

4 5 6

BL

RD

YL

YL

BN - 24VAC

V - 24VAC

BK - 120V

AC

WH - 120V

AC

GR

BK - 24VAC (HOT)

WH - 24VAC (NEUTRAL)

BL

RD

BL
RD

YL

YL

BK - 24V

AC (HOT)

WH - 24V

AC (NEUTRAL)

YL

- 24V

AC

YL

- 24V

AC

TRANSFORMER

YL

24 V

AC

GAS CONTROL VALVE/
THERMOSTAT

FV SENSOR

IGNITER/FLAME
SENSOR

BK - 120V

AC

W - 120V

AC

YL

24 V

AC

BK 24 V

AC (H)

WH 24 V

AC (N)

TEMPERATURE CUT-OFF
SWITCH

You must provide all wiring of the proper size outside of the water heater. You must obey local codes and electric
utility requirements when you install this wiring. This appliance must be electrically grounded in accordance with local codes or, in the absence of local
codes, with the National Electrical Code ANSI/NFPA No 70 (current edition) and/or THE CSA C22.1 ELECTRICAL CODE.(LATEST EDITION)
Note: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with 105

°

C wire or its equivalent.

YL

YL

ON/OFF SWITCH

END SWITCH

BN 24 V

AC

V 24 V

AC

FIGURE 23.

Disconnect power before
servicing.

Replacing all parts and
panels before operating.

Failure to do socan result in
death or electrical shock

WARNING

Electric Shock Hazard

Plug into a 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these
instructions can result in
death, fire, or electrical shock.