T&P Relief Valve and Pipe Insulation (Some Models)

1. Locate the temperature and pressure relief valve on

the water heater (also known as a T&P relief valve).

See Figure 16.

2. Locate the slit running the length of the T&P relief

valve insulation.

3. Spread the slit open and fit the insulation over the T&P

relief valve. See Figure 16. Apply gentle pressure to

the insulation to ensure that it is fully seated on the

T&P Relief Valve. Once seated, secure the insulation

with duct tape.

IMPORTANT: The insulation or tape should not block

or cover the T&P relief valve drain opening. Also, the

insulation or tape should not block or hinder access to

the manual relief lever (Figure 16).

4. Locate the hot water (outlet) & cold water (inlet) pipes

to the water heater.

5. Locate the slit running the length of a section of pipe

insulation.

6. Spread the slit open and slip the insulation over the

cold water (inlet) pipe. Apply gentle pressure along the

length of the insulation to ensure that it is fully seated

around the pipe. Also, ensure that the base of the

insulation is flush with the water heater. Once seated,

secure the insulation with duct tape.

7. Repeat steps 5 and 6 for the hot water (outlet) pipe.
8. Add additional sections of pipe insulation as needed.

T&P RELIEF VALVE

T&P RELIEF VALVE

MANUAL RELIEF LEVER

T&P RELIEF VALVE INSULATION

FIGURE 16.