Digital hours meter, Self-diagnostics function – Sony DSR-45/45P Manuel d'utilisation

Page 100

Advertising
background image

100

(GB)

Chapter 7

Maintenance

Chapter 7 Maintenance

Notes on Use

Moisture condensation is likely to occur under the
following conditions:
• The unit or cassette is brought from the cold outdoors

to a warm indoor location.

• The unit or cassette is brought from the air-

conditioned indoors to the hot outdoors.

• The unit is used in a place subject to cold currents

from an air conditioner.

When bringing the unit or cassette from a cold place to
a warm place or vice versa, put it in a plastic bag and
seal the bag tightly. After bringing it into the new
place, leave the bag on for more than one hour, and
remove the bag when the air temperature inside it has
reached the temperature surrounding it.

If moisture condensation occurred

You cannot operate the unit except to press EJECT,
and a cassette cannot be inserted. If this occurs, with
the unit powered on, remove the cassette, then wait
more than one hour for the moisture to evaporate.

Digital Hours Meter

The digital hours meter keeps cumulative counts of the
total operation time, the head drum rotation time, the
tape running time and the number of unthreading
operations. These counts can be displayed on the
menu. Use them as guidelines for scheduling
maintenance.
In general, consult your Sony dealer about necessary
periodic maintenance checks.

The digital hours meter has the following four display
modes and you can check them in HRS METER of the
OTHERS menu (See page 92 (GB)).

OPERATION mode

The cumulative total hours of operating time is
displayed in 10-hour increments.

DRUM RUN mode

The cumulative total hours of drum rotation with tape
threaded is displayed in 10-hour increments.

TAPE RUN mode

The cumulative total hours of tape running time is
displayed in 10-hour increments.

THREADING mode

The cumulative number of tape unthreading
operations is displayed in 10-operation increments.

Self-diagnostics Function

The unit has a self-diagnostics display function.
This function displays the current condition of the unit
as a five-digit code (a combination of a letter and
numbers), on the LCD monitor, display window, and
MONITOR VIDEO output. If a five-digit code is
displayed, check the following code chart. The last two
digits (indicated by ss) will differ depending on the
state of your unit.

If you are unable to resolve the problem, or a code
other than those in the above chart appears, contact
your Sony dealer or local authorized Sony service
facility and inform them of the number.

Remedy

Remove the cassette,
then wait more than
one hour with the
power on.

Clean the heads using
the cleaning cassette
(supplied).

• Remove the cassette,

or change the unit to
the standby mode
once and then turn
the unit on again.

• Disconnect the AC

power cord. After
reconnecting it,
operate the unit.

• Change the unit to the

standby mode once
and then turn the unit
on again.

• Disconnect the AC

power cord. After
reconnecting it,
operate the unit.

Code

C:21:

ss

C:22:

ss

C:31:

ss

C:32:

ss

Symptom

Moisture
condensation has
occurred.

The video heads are
dirty.

To prevent the unit
from malfunctioning,
the self-diagnostics
function has taken
over.

To prevent the unit
from malfunctioning,
the self-diagnostics
function has taken
over.

Advertising