Electrical diagrams, Schematic - amphenol bypass pc board, Commander 400 – Lincoln Electric COMMANDER 400 SVM133-B Manuel d'utilisation

Page 178

Advertising
background image

ELECTRICAL DIAGRAMS

G-6

COMMANDER 400

SCHEMATIC - AMPHENOL BYPASS PC BOARD

WITH PUBLISHED STANDARDS

J61

2

80J

150V

TP4

80J

150V

TP2

80J

150V

TP3

J61

8

J61

1

J61

3

J61

4

J61

5

80J

150V

TP1

J61

7

3000V

.0047

C1

ON 3 PLACE DECIMALS IS + .OO2

TO MOTHER CONTROL PCB

.39mH

L3

.39mH

L2

TO "OUTPUT CONTROL SOURCE" SWITCH

76C

3000V

.0047

C4

3000V

.0047

C5

3000V

.0047

C2

3000V

.0047

C6

.39mH

L5

.39mH

L1

3000V

.0047

C3

.39mH

L6

.39mH

L4

77C

2B

75B

M

MATERIAL TOLERANCE ("t") TO AGREE

ON ALL ANGLES IS + .5 OF A DEGREE

UNLESS OTHERWISE SPECIFIED TOLERANCE

ON HOLES SIZES PER E-2056

Ch’ge.Sht.No.

ON 2 PLACE DECIMALS IS + .O2

17900

NUMBER.

NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE

WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY

NOTES :

N.A. SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE

TO "REMOTELOCAL" SWITCH

4B

J62

5

J62

3

J62

6

J62

4

J60

2

J60

6

J60

5

J62

1

J62

2

J60

3

J60

4

2D

4D

2E

4E

75E

77D

1A, 400V

ELECTRICAL SYMBOLS PER E1537

DIODES =

GENERAL INFORMATION

(

1/4W

.022/50V

76D

3/9/95

DR.

SCALE

DATE

J60

1

POWER SUPPLY SOURCE POINT

EARTH GROUND CONNECTION

UNLESS OTHERWISE SPECIFIED)

UNLESS OTHERWISE SPECIFIED)

LABELS

(UNLESS OTHERWISE SPECIFIED)

77E

76E

FILENAME: M17900_1AB

C-

17900

SUP’S’D’G.

R-

EQUIP.

NONE

NO.

SHT.

LAST NO. USED

RESISTORS = Ohms (

CAPACITORS =

MFD

SUBJECT

TYPE

CLEVELAND, OHIO U.S.A.

6

COMMANDER 400 STICK & WIRE

L-

M

M

CHK.

THE LINCOLN ELECTRIC CO.

SUPPLY

VOLTAGE NET

FRAME CONNECTION

COMMON CONNECTION

_

6

I.E.B. / F.V.

AMPHENOL BYPASS SCHEMATIC

75D

XB-UF

12-13-96

JB

G-6

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.

Advertising