Troubleshooting and repair, Shunt calibration test (continued), Warning – Lincoln Electric COMMANDER 400 SVM133-B Manuel d'utilisation

Page 116: Pin #2 +pin #3 plug j1, Test procedure, Figure f.29 control board plug j1

Advertising
background image

TROUBLESHOOTING AND REPAIR

SHUNT CALIBRATION TEST (continued)

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TEST PROCEDURE

NOTE:

In this test procedure, the positive output

stud is used for common.

1.

Using the 5/16” nut driver, open the control panel
and tilt out. Remove the control board cover.
Start the machine.

There are high voltages present
inside the control box while the
machine is running. THE VOLTAGES
ARE HIGH ENOUGH TO KILL. Use
extreme caution to avoid the back-
side of the receptacles, breakers, and

terminal strip while checking voltages inside the
control box.

2. Set the range switch to the CC/General fabrica-

tion tap. Using the fine control pot, set the pre-
set amps on the display to 300 amps.

3.

Using a grid bank, load the machine to 300 amps
at 25 volts using an external ammeter and volt-
meter.

4.

At the control board, measure the voltage from
J1 pin 3 (pos. lead) to J1 pin 2 (neg. lead). See
Figure F.29. The voltage should be 25 mVDC +/-
5%. The current reading on the display should
be within +/- 5% with the external ammeter. See
Figure F.29.

5.

If step 4 fails, the shunt is out of calibration and
must be replaced.

6.

If the test is complete, replace the control board
cover and close the control panel.

WARNING

F-62

F-62

COMMANDER 400

Figure F.29 Control Board Plug J1

J2

J6

J5

J8

J7

J1

J4

J22

J20

C112

-Pin #2

+Pin #3

Plug J1