TROUBLESHOOTING AND REPAIR

RANGE SWITCH TEST (continued)

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TEST PROCEDURE

NOTE:

In this test procedure, the positive output

stud is used for common.

1.

Using the 5/16” nut driver, open the control panel
and tilt out. Remove the control board cover.
Start the machine.

There are high voltages present inside
the control box while the machine is
running. THE VOLTAGES ARE HIGH
ENOUGH TO KILL. Use extreme cau-
tion to avoid the backside of the
receptacles, breakers, and terminal

strip while checking voltages inside the control
box.

2. Put the range switch in the CV position on stick &

wire machines, or in the 90 tap on stick only
machines.

3.

Check the voltage at the control board from J7
pin 10 to common at each tap on the range
switch. See Figure F.28. See table F.1 below for
approximate voltage reading from each tap.

4.

If any of the voltages in the table are incorrect,
replace the range switch.

5.

If the test is complete, replace the control board
cover and close the control panel.

WARNING

CV tap

90 tap

120 tap

180 tap

230 tap

270 tap

400 tap

50-575 tap

.580 Vdc (if so equipped)

.937 Vdc

1.29 Vdc

1.65 Vdc

2.00 Vdc

2.36 Vdc

2.69 Vdc

3.06 Vdc

Range Switch Position

Voltage

F-58

F-58

COMMANDER 400

Table F.1