Troubleshooting & repair, Commander 400 – Lincoln Electric COMMANDER 400 SVM133-B Manuel d'utilisation

Page 145

Advertising
background image

TROUBLESHOOTING & REPAIR

F-91

F-91

COMMANDER 400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

SCR/DIODE RECTIFIER BRIDGE

REMOVAL AND REPLACEMENT

(continued)

FIGURE F.38 – NEGATIVE “STICK” OUTPUT TERMINAL

#207 FROM STICK
OUTPUT TERMINAL

COMMANDER 400

STICK and WIRE

STICK and WIRE

WIRE

WIRE

STI

STI

+

9. Using the 3/4" wrench, remove lead #207 from

the negative "stick" output terminal. See
Figure F.38 and the Wiring Diagram. Cut any
necessary cable ties.

10. Locate and remove the snubber board cover

using the 3/8" wrench. See Figure F.39.

11. Remove plug J30 from the snubber board.

See the Wiring Diagram. Clear leads for the
SCR/diode rectifier bridge assembly
removal.

FIGURE F.39 – SNUBBER BOARD COVER REMOVAL

SNUBBER
BOARD
LOCATION
(LEFT SIDE,
BELOW
FUEL TANK)

Advertising