Troubleshooting & repair, Commander 400 – Lincoln Electric COMMANDER 400 SVM133-B Manuel d'utilisation

Page 144

Advertising
background image

TROUBLESHOOTING & REPAIR

F-90

F-90

COMMANDER 400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

SCR/DIODE RECTIFIER BRIDGE

REMOVAL AND REPLACEMENT

(continued)

FIGURE F.37 – SCR/DIODE RECTIFIER BRIDGE DETAILS

#209 (small)

#209A (large)

#204C

STATOR WELD
WINDING LEADS

SHUNT
REMOVE BOLT
AT POSITIVE
HEAT SINK
PLATE (LOWER)

COMMANDER 400

STICK and WIRE

STICK and WIRE

WIRE

WIRE

STI

STI

+

PROCEDURE

1. Turn the engine off.

2. Perform

the

Case Cover Removal

Procedure (including front shroud removal).

3. Using the 1/2" wrench, remove the stator weld

winding leads from the SCR/diode rectifier
bridge assembly. See Figure F.37 and the
Wiring Diagram. Cut any necessary cable ties
and clear the leads.

4. Using the 1/2" wrench, remove lead #209

(small) and #209A (large) from the negative
(upper) heat sink plate. See Figure F.37 and
the Wiring Diagram.

5. Using the 1/2" wrench, remove the heavy

#204C lead from the positive heat sink plate
(lower). See Figure F.37 and the Wiring
Diagram.

6. Using the 1/2" wrench, remove the shunt

from the positive heat sink plate (lower). See
Figure F.37 and the Wiring Diagram.

NOTE: The "DD" diode pigtail lead and the three
small #204, #204A and #204B leads are also
incorporated in the bolted connection. They can
stay in place.

7. Using the 5/16" nut driver, remove the control

board cover.

8. Remove plug J6 and the toroid assembly from

the control board. Remove plug J6 and leads
from the control box. Cut any necessary cable
ties.

Advertising