Troubleshooting & repair – Lincoln Electric COMMANDER 400 SVM133-B Manuel d'utilisation

Page 162

Advertising
background image

TROUBLESHOOTING & REPAIR

F-108

F-108

COMMANDER 400

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT

(continued)

FIGURE F.52 – SHUTDOWN SOLENOID LEAD REMOVAL

PULL-IN COIL
(LARGER TERMINALS
EACH SIDE
#225 AND #262)

HOLD-IN COIL
(SMALLER TERMINALS
EACH SIDE
#224 AND #240)

IDLER
SOLENOID

SHUTDOWN
SOLENOID

12. Label and remove the four leads #224, #240,

#225 and #262 from the shutdown solenoid.
See Figure F.52. Cut any necessary cable
ties.

13. Label and remove leads #226, #237, #227

and #254 from the idler solenoid. See Figure
F.53 Cut any necessary cable ties.

FIGURE F.53 – IDLER SOLENOID LEAD REMOVAL

PULL-IN COIL
(LARGER TERMINALS
TOP AND BOTTOM
#227 AND #254)

HOLD-IN COIL
(SMALLER
TERMINALS
TOP AND BOTTOM
#226 AND #237)

IDLER
SOLENOID

SHUTDOWN
SOLENOID

Advertising