STATOR VOLTAGE TEST

(continued)

FIGURE F.24 – SCR/DIODE RECTIFIER BRIDGE LEADS

COMMANDER 400

STICK and WIRE

STICK and WIRE

WIRE

WIRE

STI

STI

+

W2/W5

W1/W4

W3/W6

TEST PROCEDURE – Weld and PC
Board Windings Test

7. Check for 48-55VAC at leads W1/W4 to leads

W2/W5 located at the SCR/Diode Bridge. See
Figure F.24 and the Wiring Diagram.

8. Check for 48 - 55VAC at leads W2/W5 to leads

W3/W6 located at the SCR/Diode Bridge. See
Figure F.24 and the Wiring Diagram.

9. Check for 48 - 55VAC at leads W3/W6 to leads

W1/W4 located at the SCR/Diode Bridge. See
Figure F.24 and the Wiring Diagram.

10. Check for approximately 42VAC at leads E1

to E2 located at plug J2 on the control board.
See Figure F.25. Do not remove the plug from
the control board.

If any of the above voltage checks are low or
missing, check the associated leads for loose or
faulty connections. See the Wiring Diagram.
Then proceed to the Exciter Winding Voltage
Test