ABNORMAL EXCITER VOLTAGE FEEDBACK WAVEFORMS

1 V

2 ms

This is an example of a bad wave-
form at one of the Exciter Module
outputs (J4 pin 3 to pin 7).

Note: The distortion in the waveform

that causes the period to be in
excess of 9.5 ms. Any distor-
tion that causes a period in
excess of 9.0 ms requires the
Exciter Module to be replaced.
This distorted waveform can
cause machine shutdowns
with “CSS”, “ECL”, & “ECH”
error codes on the display,
and can cause “CRS” and “---”
error codes at power-up. It
can also cause flare-ups and
welds that are too hot, “spat-
tery”, or “cannon balling”.

SCOPE SETTINGS