TROUBLESHOOTING & REPAIR

F-72

F-72

COMMANDER 400

This is the typical auxiliary output
voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.

Note: Scope probes connected at
machine 115VAC receptacle.

SCOPE SETTINGS

Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)

HIGH IDLE – NO LOAD – OUTPUT CURRENT CONTROL AT MAXIMUM

0 volts

15.8 ms