ENGINE, STATOR/ROTOR REMOVAL AND REPLACEMENT

(continued)

FIGURE F.56 – ENGINE GROUNDING LEAD

ENGINE GROUNDING

LEAD ATTACHMENT

POINT

16. Using the 11/16" socket wrench, remove the

grounding lead from the top of the engine
bell housing. See Figure F.56.

17. Cut any necessary cable ties to free the har-

ness assembly from the engine/stator
assembly.

18. Using the 11/16" wrench, remove leads

#236A, #236B and #236C from the starter
motor solenoid.

19. Using the slot head screw driver, remove

lead #231A

and #231B from the starter

motor solenoid.

20. Label and remove the #239 lead from the

engine alternator using the 3/8" wrench.

21. Label and remove the #285 lead from the

engine alternator using the 3/8" wrench.

22. Label and remove the #238 lead from the

engine alternator using the 7/16" wrench.

23. Clear the wiring harness for engine/stator

removal by cutting any necessary cable ties.

24. Using the 1/2" wrench, remove the three

bundled leads (W1-W4, W2-W5 and W3-W6)
from the SCR/diode rectifier bridge assembly.