Troubleshooting & repair, Active scr test (continued), Test procedure – Lincoln Electric COMMANDER 400 SVM133-B Manuel d'utilisation

Page 100

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-46

F-46

COMMANDER 400

ACTIVE SCR TEST

(continued)

FIGURE F.17 – CONTROL BOARD PLUG J6 LOCATION

PLUG J6

P e l 9 9 6

TEST PROCEDURE

1. Turn OFF the engine.

2. Perform the Case Removal procedure

(including front shroud removal).

3. Disconnect the welding cables from the

welding output terminals.

4. Using the 5/16” nut driver, remove the con-

trol board cover. See Figure F.17.

5. Locate and remove molex plug J6 from the

control board. See Figure F.17.

6. Using the 3/8” nut driver, locate and remove

the snubber board cover. See Figure 18.

7. Locate and remove molex plug J30 from the

snubber board. See Figure F.18.

FIGURE F.18 – SNUBBER BOARD PLUG J30 LOCATION

PLUG J30

COMMANDER SNUBBER

C3

C1

C2

C7

WARNING

SNUBBER
BOARD
LOCATION
(LEFT SIDE,
BELOW
FUEL TANK)

Advertising