Specifications – Garland MASTER SERIES HEAVY DUTY GAS RANGES AND CHAR BROILERS, ALL M/MS/MST SERIES MODELS Manuel d'utilisation

Page 4

Advertising
background image

Part # 1382680 Rev 3 (05/10/11)

Page 4

SPECIFICATIONS

MODEL NUMBER

GAS TYPE NATURAL GAS TYPE-PROPANE

INPUT (BTU/H)

INPUT (BTU/H)

(M,MS)(12,43) Open Burner

24,000

20,000

MST43 Open Burner

24,000

20,000

M(M43-1,2,3),12S-6 Hot top burner

22,000

22,000

M43 FTR Front Open Burner

18,000

16,000

Rear French top

15,000

16,000

(M, MS)(4,42,44,54) Open Burner

35,000

35,000

MST(42,44,54) Open burner

35,000

35,000

(M,MS)(45,54,5) Spectro Heat Burner

15,000

11,000

MST45 Spctro Heat Burner

Total of 3 burners

40,000

Total of 3 burners

40,000

M(42-6,46,6) Even Heat Hot Top Burner.

30,000

30,000

MST(42-6,46,6) Even Heat Hot Top Burner

27,000

27,000

(M,MS)47 Griddle burner

33,000

33,000

MST 47 Griddle Burner

30,000

30,000

M48 Griddle Burner

33,000

33,000

(M,MS,MST) Oven Burner

40,000

35,000

(M,MS,MST)(17,24,34) Char-Broiler

15,000

15,000

(M1R) Single deck oven section

40,000

40,000

(M2R) Double stacked ovens

80,000

80,000

Natural Gas Operating Pressure=6.0” Water Column, measured at manifold tap.

Propane Gas Operating Pressure=10.0” Water Column, measured at manifold tap.

Clearance from Combustible Construction

Models (M,MST)5(S,T) & (M,MST)45(R,RC,S,T) must be

installed with no less than six inch (6”) clearance from

combustible construction at sides and rear .

Models (M,MS,MST)42(R,RC,S,T), (M,MS,MST)

44(R,RC,S,T), (M,MS,MST)54(R,RC,S,T), (M,MS,

MST)4(S,T), (M,MST)46(R,RC,S,T), (M,MST)47

(R,RC,S,T), M47-23(R,RCS,T), M47-45(R,RC,S,T), M48(R,RCS,T),

M48-23(R,RC,S,T), M48-45(R,RC,S,T) (M,MST)(6,7,8)(S,T) must

be installed with no less than fourteen inches (14”) on the

side, and six inch (6”) rear clearance from combustible

construction .

Models (M,MS,MST)43(R,RC,S,T) must be installed with no less

than eleven inch (11”) side and six inch (6”) rear clearance

from combustible construction .

Clearance from Non-Combustible

Construction

Models (M,MS,MST)(17,24,34)B(E) are for INSTALLATION IN

NON-COMBUSTIBLE LOCATIONS ONLY with zero (0”) sides

and rear clearance . Models with suffix “RC” must be installed

with zero inches (0”) side and no less than one inch (1”) rear

clearance from non-combustible construction. All other

models may be installed with zero inches (0”) sides and rear

clearance from non-combustible construction.