Analog Way Ultra VIO - VU301-IOD1 Manuel d'utilisation

Page 27

Advertising
background image

VIO1600 & ULTRA VIO

Chapter 6 : REMOTE CONTROL SOFTWARE (continued)

PAGE 27

6-3. COMMUNICATION SETUP (continued)

CASE OF LAN PORT:
- With the front panel display menu of the device, verify the configuration of the LAN communication port
(CONTROL > LAN setup), then activate the LAN communication port (CONTROL > RS232/LAN port >
LAN
).
- With the Controls menu of the software, select RS232/LAN setup and LAN Setup. Then configure the Local
port
, the Remote IP address and the Remote port and click on Apply to setup the new values. The software will
also display Device connected.
NOTE: To verify the LAN status of your device: Select LAN status in the Controls menu.

6-4. USING THE SOFTWARE

c Click on the Input tab and select the Signal Type for each input. Then make the others adjustments (video

Standard...) and disable the unused inputs (Used section).