Rockwell Automation Publication 1756-UM020I-EN-P - August 2012

77

Add, Configure, Monitor, and Replace CIP Safety I/O

Chapter 5

A CIP Safety I/O device address follows this format:

Modulename:Type.Member

Monitor Safety I/O Module
Status

You can monitor safety I/O module status via explicit messaging or via the status
indicators on the I/O modules.

These publications provide information on I/O module troubleshooting:

Guard I/O DeviceNet Safety Modules User Manual, publication

1791DS-UM001

Guard I/O EtherNet/IP Modules User Manual, publication

1791ES-UM001

POINT Guard I/O Safety Modules Installation and User Manual,

publication

1734-UM013

Table 20 - CIP Safety I/O Module Address Format

Where

Is

Modulename

The name of the CIP Safety I/O module

Type

Type of data

Input: I

Output: O

Member

Specific data from the I/O module

Input-only Module:

Modulename:I.RunMode
Modulename:I.ConnectionFaulted
Modulename:I.Input Members

Output-only Module:

Modulename:I.RunMode
Modulename:I.ConnectionFaulted
Modulename:O.Output Members

Combination I/O:

Modulename:I.RunMode
Modulename:I.ConnectionFaulted
Modulename:I.Input Members
Modulename:O.Output Members

Table 21 - Additional Resources

Resource

Description

Chapter 9

,

Monitor Status and Handle Faults

Contains information on monitoring safety tag data

Logix5000 Controllers I/O and Tag Data Programming
Manual, publication

1756-PM004

Provides information on addressing standard I/O modules

Advertising