Programming requirements – Rockwell Automation 1756-SPESMNRMXT GuardLogix Controllers User Manual Manuel d'utilisation
Page 21

Rockwell Automation Publication 1756-UM020I-EN-P - August 2012
21
System Overview
Chapter 1
Programming Requirements
RSLogix 5000 software is the programming tool for GuardLogix controller
applications.
Use
to identify the minimum software versions for use with your
GuardLogix controllers. RSLogix 5000 software, version 15, does not support
Safety Integrity Level (SIL) 3.
Safety routines include safety instructions, which are a subset of the standard
ladder logic instruction set, and safety application instructions. Programs
scheduled under the safety task support only ladder logic.
For information on using these features, refer to the Logix5000 Controllers
Common Procedures Programming Manual, publication
publications listed in the
Additional Resources on page 13
, and RSLogix 5000
software online help.
Table 7 - Software Versions
Cat. No.
RSLogix 5000 Software
Version
(1)
(1) This version or later.
RSLinx
®
Classic Software
Version
1756-L61S, 1756-L62S
14
Any version
1756-L63S
16
1756-L71S, 1756-L72S, 1756-L73S,
1756-L73SXT
20
2.59
Table 8 - Supported Features by RSLogix 5000 Software Version
Feature
Version 14
Version 16
Version 17
Version 18
Version 19
Version 20
Sa
fe
ty
T
as
k
Sta
n
da
rd
T
ask
Sa
fe
ty
T
as
k
Sta
n
da
rd
T
ask
Sa
fe
ty
T
as
k
Sta
n
da
rd
T
ask
Sa
fe
ty
T
as
k
Sta
n
da
rd
T
ask
Sa
fe
ty
T
as
k
Sta
n
da
rd
T
ask
Sa
fe
ty
T
as
k
Sta
n
da
rd
T
ask
Add-On Instructions
X
X
X
X
X
X
X
X
Alarms and events
X
X
X
X
X
Controller logging
X
X
X
X
X
X
X
X
Data Access Control
X
X
X
X
X
X
Equipment phase routines
X
X
X
X
X
Event tasks
X
X
X
X
X
Firmware Supervisor
X
X
X
X
X
X
X
X
Function block diagrams (FBD)
X
X
X
X
X
Integrated motion
X
X
X
X
X
Ladder logic
X
X
X
X
X
X
X
X
X
X
X
X
Language switching
X
X
X
X
X
X
X
X
Memory card
X
X
X
X
X
X
Online import and export of
program components
X
X
X
X
Sequential function chart (SFC)
routines
X
X
X
X
X
Structured text
X
X
X
X
X
Unicast connections for produced
and consumed safety tags
X
X
X
X
Unicast connections for safety I/O
modules on EtherNet/IP networks
X
X
- 1756-SPESMNRM GuardLogix Controllers User Manual 1756-SPESMNSEXT GuardLogix Controllers User Manual 1756-SPESMNSE GuardLogix Controllers User Manual 1756-ESMNRMXT GuardLogix Controllers User Manual 1756-ESMNRM GuardLogix Controllers User Manual 1756-ESMNSEXT GuardLogix Controllers User Manual 1756-ESMNSE GuardLogix Controllers User Manual 1756-ESMCAPXT GuardLogix Controllers User Manual 1756-ESMCAP GuardLogix Controllers User Manual 1756-L7x GuardLogix Controllers User Manual 1756-LSP GuardLogix Controllers User Manual 1756-L6x GuardLogix Controllers User Manual