Parity check, Stop bit, Wait time – Panasonic WJ-HD500 Manuel d'utilisation
Page 63: Aiarm data, Input (camera) number setup
Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

• Parity Check
This item lets you set the parity bit for RS-485 communica
tion.
1. Move the cursor to the PARITY CHECK parameter by
pressing the
A
or
T
button.
2. Select NONE, EVEN or ODD for parity check by press
ing the (±) or E) button.
The factory default setting is NONE.
• Stop Bit
This item lets you set the number of stop bits for RS-485
communication.
1. Move the cursor to the STOP BIT parameter by press
ing the
A
or ▼ button,
2. Select either 1 or 2 for the number of stop bits by press
ing the (±) or Q button.
The factory default setting is 1 bit.
• Wait Time
This item lets you set the waiting time in milli-seconds (ms)
to retry after confirming that no data is received from the
controller for RS-485 communication.
1. Move the cursor to the WAIT TIME parameter by press
ing the
A
or ▼ button.
2, Select OFF, 100, 200, 400, 1 000 ms for the wait time by
pressing the Ш or 0 button.
When no transmission is needed, select OFF.
The factory default setting is OFF (no retry).
• Aiarm Data
This item lets you enable or disable notification of the alarm
data received to the controller (Unit Number 1).
1. Move the cursor to the ALARM DATA parameter by
pressing the
A
or
T
button.
2. Select the desired mode by pressing the 0 or 0 but
ton.
OFF:
Select this parameter if the system controller is
not connected to the system.
OS:
Each time an alarm is received, it is transmitted to
the system controller.
IS:
The received alarm is stored for 1 second, and that
data is sent to the system controller.
5S:
The received alarm is stored for 5 seconds, and
that data is sent to the system controller.
The factory default setting is IS.
• Input (Camera) Number Setup
This item lets you assign numbers for the input from the
system cameras for RS-485 communication.
1. Move the cursor to CAMERA NUMBER SETUP by
pressing the
A
or
T
button, then press the
SET
button.
The CAMERA NUMBER SETUP table shown below
appears on the monitor screen.
-
9-1-1
CAMERA mniBER
SETUP
CAM-PORT СЛИ NO.
CAM-PORT CAM HO.
1
001
9
009
2
002
10
010
3
003
11
Oil
4
004
12
012
5
005
13
013
6
00Б
14
014
7
007
15
015
8
008
16
016
2. Move the cursor to the input (CAM-PORT) parameter to
edit by pressing the
A , T ,
or ► button, then select
a camera number by pressing the 0 or B button,
—: No assignment,
001 -128:
Assigns the selected number.
Note:
Make sure not to assign the same number to
more than one system camera for RS-485 communi
cation.
3. Repeat the above procedure to edit other input para
meters.
4. After completing the settings, press the
SETUP/ESC
button to return to the previous setup menu.
64