Alarm, Alarm port connection – Panasonic WJ-HD500 Manuel d'utilisation
Page 18
Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

The ALARM port can be used for connecting the alarm sen
sor and alarm control switches. It is also used to synchro
nize the sequence as shown below.
• Connect the sensor switches to the ALARM port on the
rear of the Disk Recorder, as shown in the example
beiow.
■ Alarm Port Connection
The sequence timing can be assigned to one of the
recorders when the multiple Disk Recorders are
equipped in the system.
Connect the CONTROL port and ALARM port as shown
below.
Refer to the SEQ TIMING in the SEQUENCE SETUP
menu for further setting.
Sequence Timing Output
Sequence Timing Input
_________ 1
Ground Ground
5
_
•7^ .....................................bJ
15
CONTROL
WJ-HD500{1St)
ALARM
WJ-HD500 (2nd)
If the sequence timing is controlied from the outboard
device, the input signai is required as shown in the fig
ure. For example, the WJ-HD500 output is also in the
figure.
input
100 ms 100 ms
WJ-HD500
output
Pin
No.
Designation
Pin
No.
Designation
1 Alarm Input 1
14 Ground
2 Alarm Input 2
15 Alarm Input 5
3
Alarm Input 3
16 Alarm Input 6
A Alarm Input 4
17 Alarm Input 7
5
Sequence Timing Input
18 Alarm Input 8
6
Alarm Reset Output
19 Alarm Input 9
7 Ground
20 Ground
8
Alarm Recover Input
21 -1-5 V Output (0.2 A)
9
Alarm Output
22
Recording Timer Select
Input
10 Alarm Input 10
23 Alarm Input 14
11 Alarm Input 11
24 Alarm Input 15
12 Alarm Input 12
25 Alarm Input 16
13 Alarm Input 13
500 ms 100 ms