Rockwell Automation 1440-DYN02-01RJ XM Dynamic Measurement Module Manuel d'utilisation
Page 95

Publication ICM-UM002F-EN-E - March 2013
95
I/O Data Tags
Apendix A
(1)
The input data type name varies depending on the measurements you select in the Channel Data tab in the
RSLogix 5000 software AOP.
See Configure the Module Definition Properties on page 60
.
(2)
The measurement appears in the input data type only if you select it in the Channel Data tab.
Module Definition Properties on page 60
Ch0Vector2XPhase
(2)
REAL
The measured phase of the vibration at 2 times the machine speed for
Channel 0.
Ch0Vector3XMagnitude
(2)
REAL
The measured magnitude of the vibration at 3 times the machine speed
for Channel 0.
Ch1Overall
(2)
REAL
The measured overall value for Channel 1. Overall measures the
amplitude of the vibration signal at all frequencies.
Ch1DCBiasGap
(2)
REAL
The measured average DC offset of the transducer signal for Channel 1.
Ch1SumHarmonics
(2)
REAL
The sum of the amplitude of the harmonics in the range from the
specified starting order through the frequency maximum for Channel1.
Ch1Not1X
(2)
REAL
The measured magnitude of the vibration excluding the vibration at the
machine speed for Channel 1.
Ch1Band0
(2)
REAL
The measured band values for Channel 1.
Ch1Band1
(2)
REAL
Ch1Band2
(2)
REAL
Ch1Band3
(2)
REAL
Ch1Vector1XMagnitude
(2)
REAL
The measured magnitude of the vibration at the machine speed for
Channel 1.
Ch1Vector1XPhase
(2)
REAL
The measured phase of the vibration at the machine speed for Channel
1.
Ch1Vector2XMagnitude
(2)
REAL
The measured magnitude of the vibration at 2 times the machine speed
for Channel 1.
Ch1Vector2XPhase
(2)
REAL
The measured phase of the vibration at 2 times the machine speed for
Channel 1.
Ch1Vector3XMagnitude
(2)
REAL
The measured magnitude of the vibration at 3 times the machine speed
for Channel1.
Speed
(2)
REAL
The measured speed value for the machine.
MaxSpeed
(2)
REAL
The maximum speed value for the machine. This is the greatest
measured speed value since the most recent reset. You can reset the
Maximum Speed using MaxSpeedReset in the output tag.
Acceleration
(2)
REAL
The measured acceleration value for the machine. The acceleration is
the rate of change in the speed.
SMAXMagnitude
(2)
REAL
The greatest peak magnitude around the orbit.
SMAXPhase
(2)
REAL
The phase at which the greatest peak magnitude occurs around the
orbit.
Module-defined Data Type: AB:1440_VDP_7FFFFFFF:I:0
(1)
Member Name
Type
Location
Description