Services, Devicenet object (class code 03h), Class attributes – Rockwell Automation 1440-DYN02-01RJ XM Dynamic Measurement Module Manuel d'utilisation
Page 106: Instance attribute, Class attributes instance attribute, Devicenet object (class code 03

106
Publication ICM-UM002F-EN-E - March 2013
Appendix B CIP Objects
Services
DeviceNet Object
(Class Code 03
H
)
The DeviceNet Object is used to provide the configuration and status of a
physical attachment to DeviceNet.
Class Attributes
Instance Attribute
Identity Object Services
Service
Code
Class/Instance Usage
Name
01
h
Instance
Get_Attributes_All
05
h
Instance
Reset
0E
h
Instance
Get_Attribute_Single
10
h
Instance
Set_Attribute_Single
DeviceNet Object Class Attributes
Attr ID
Access
Name
Data Type
Default Value
1
Get
Revision
UINT
2
DeviceNet Object Instance Attributes
Attr ID
Access
Name
Data Type
Default Value
1
Get
MAC ID
USINT
On DIP switches under label
2
Get
Baud Rate
USINT
The baud rate is determined by automatic
baud rate detection (autobaud). The module
listens to network traffic to determine the
baud rate before it goes online.
3
Get
Bus-Off Interrupt
BOOL
0
4
Get/Set
Bus-Off Counter
USINT
0
5
Get
Allocation Information
STRUCT of
BYTE
USINT
0 255
100
Get
Autobaud Disable
BOOL
0 (always autobaud)