Installation & Servicing Instructions Rinnai Q-Series

85

no signal from the fan

the fan is not

spinning

fuse is working

and the error is

repeated

wiring and voltage

are OK and error

is repeated

if necessary,

replace the fan

check fuse F3, this fuse is positioned in the
control unit and can be seen once the black
covering lid has been removed

check the wiring to the fan and the control unit
and/or the 24 volt power supply to the fan

check for any possible contamination, which

might be impeding the fan impeller or
check the air temperature in the airbox.
When temperature is higher than 158°F

find cause and take precautions for
repeating

16.2.14 Erreur / Error 28

le ventilateur ne

tourne pas

le fusible

fonctionne et

l’erreur persiste

le câblage et la

tension sont OK et

l’erreur persiste

remplacez le

ventilateur si

nécessaire

aucun signal du ventilateur

vérifiez le fusible F3 ; ce fusible est placé dans
l’appareil de contrôle et se voit en retirant le
couvercle noir

vérifiez le câblage du ventilateur et de l’appareil
de contrôle et/ou l’alimentation électrique en
24 Volt du ventilateur

vérifiez l’absence de toute contamination

possible, pouvant gêner la turbine du

ventilateur ou vérifiez la température
de l’air dans la boîte à air. Lorsque
la température est supérieure à 158°
F, recherchez la cause et prenez les
précautions avant de répéter