4 warranty – Rinnai Q130SN Manuel d'utilisation

Page 64

Advertising
background image

Installation & Servicing Instructions Rinnai Q-Series

64

Visual inspection of the flame

The burner must flame evenly over the entire surface when operating correctly. The

flame must burn with a clear, blue, stable flame.

Check the flame through the inspection glass in the ignition probe (fig. 39).

The flame pattern should be as shown in the figures below.

Further checks:

- Inspect the pressure relief valve

- Clean the water filter in the return pipe

- Check the pH of the water or glycol/water mixture.

Verify proper operation after servicing.

14.4 Warranty

For warranty conditions refer to the warranty card supplied with the boiler.

SATISFACTORY

Ignition probe

blue flame

UNSATISFACTORY

Ignition probe

yellow flame

Inspection glass

figure 39

Advertising
Ce manuel est liée aux produits suivants: