10

facts to consIder aBout the locatIon

Carefully choose an indoor location for the new water heater, because

the placement is a very important consideration for the safety of the

occupants in the building and for the most economical use of the

appliance.

this water heater is not for use in manufactured

(mobile) homes or outdoor installation.

Whether replacing an old water heater or putting the water heater

in a new location, the following critical points must be observed:

1. Select a location indoors as close as practical to the vent terminal

or location to which the water heater vent piping is going to be

connected, and as centralized with the water piping system as

possible.

2. Selected location must provide adequate clearances for

servicing and proper operation of the water heater.

Installation of the water heater must be accomplished in such a

manner that if the tank or any connections should leak, the flow

will not cause damage to the structure. For this reason, it is not

advisable to install the water heater in an attic or upper floor. When

such locations cannot be avoided, a suitable drain pan should be

installed under the water heater. Drain pans are available at your

local hardware store. Such a drain pan must have a clearance of

at least 1.0” (2.5cm) greater than any point on the water heater’s

outer jacket and must be piped to an adequate drain. The pan must

not restrict combustion air flow. For example, if a circular pan is

used, it must be a minimum of 27” (69cm) in diameter. See Figure 1.

Water heater life depends upon water quality, water pressure and the

environment in which the water heater is installed. Water heaters are

sometimes installed in locations where leakage may result in property

damage, even with the use of a drain pan piped to a drain. However,

unanticipated damage can be reduced or prevented by a leak detector

or water shut-off device used in conjunction with a piped drain pan.

These devices are available from some plumbing supply wholesalers

and retailers, and detect and react to leakage in various ways:

• Sensors mounted in the drain pan that trigger an alarm or turn off the

incoming water to the water heater when leakage is detected.

• Sensors mounted in the drain pan that turn off the water supply to

the entire building when water is detected in the drain pan.

• Water supply shut-off devices that activate based on the water

pressure differential between the cold water and hot water pipes

connected to the water heater.

• Devices that will turn off the gas supply to a gas water heater while

at the same time shutting off its water supply.

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQUIDS

(VAPORS) ARE LIKELY TO BE PRESENT OR STORED

(GARAGES, STORAGE AND UTILITY AREAS, ETC.): Flammable

liquids (such as gasoline, solvents, propane (LP or butane, etc.) and

other substances (such as adhesives, etc.) emit flammable vapors

which can be ignited by a gas water heater’s hot surface igniter or

main burner. The resulting flashback and fire can cause death or

serious burns to anyone in the area.

Also, the water heater must be located and/or protected so it is not

subject to physical damage by a moving vehicle.

locatInG the new water heater

This water heater must not be installed directly on carpeting.

Carpeting must be protected by metal or wood panel beneath the

appliance extending beyond the full width and depth of the appliance

by at least 3” (7.6 cm) in any direction, or if the appliance is installed

Advertising