Band Pass Filter Options

The Band Pass Filter options apply to the Band Pass Filter measurement mode
and affect the Band Pass Filter measurement.

Thrust Position Measurement Options

The Thrust Position measurement options apply to the Thrust Position
measurement mode and affect the Thrust Position measurement.

In this field

Values are

Comments

Min Frequency

25 to 1000 Hz

The high pass corner frequency or low cutoff frequency of the
band pass filter.

Max Frequency

100 to 5500 Hz

The low pass corner frequency or high cutoff frequency of the
band pass filter.

Parameter Name

Values are

Comments

Output data unit

Select mil or μm.

The units of the Thrust Position measurement
value.

Target Angle

Sets the angle between the shaft and the target surface. The target
surface moves with the shaft. The transducer is mounted
perpendicular to the target surface.

degrees

Upscale

Sets the movement of the target relative to the transducer that is
considered positive displacement.

Options:
Away
Towards

Calibration Offset (XM Serial Configuration Utility
only)

Enter the position of the current Transducer DC Bias reading.

mils