Rockwell Automation 1440-SDM02-01RA XM-124 Standard Dynamic Measurement Module Manuel d'utilisation

Page 72

Advertising
background image

72

Rockwell Automation Publication 1440-UM001C-EN-P - May 2014

Chapter 2

Configure the XM-124 Standard Dynamic Measurement Module

Frequency Maximum

Enter the upper limit of the range of spectrum bins to be included in the
band measurement, and the frequency units (Hz or Orders). Set the
value by using the table below.

This value must be greater than the Band Frequency
Minimum.
When integrating, the Maximum Frequency may not be set
greater than the 2 kHz analog LPF that is applied to all
integrating measurements.

Frequency Minimum

Enter the spectrum bin with the least frequency to be included in the
band measurement.

In this field

Values are

Comments

Sampling
Mode

Spectrum
Frequency Max
Units

Band Units

Band Frequency
Max

Synchronous

Orders

Hz

0…5000

Orders

0.01…200

Asynchronous

Hz

Hz

0…20,000

Orders

0.01…200

IMPORTANT

For bands specified in Hz on an orders-based spectrum (Sampling Mode set
to Synchronous with tach), the band measurement value is zero when the
Band Frequency Minimum and Frequency Maximum fall completely
beyond the frequencies represented in the spectrum. If any of the band falls
within the spectrum, only that portion contributes to the band value.

Example

Band Frequency Maximum = 250 Hz

Band Frequency Minimum = 150 Hz

Spectrum Frequency Maximum = 10 Orders

The following table shows the actual Band Frequency Maximum and
Minimum values given different operating speeds for this example. Note
that when the speed is 600 rpm, the Band Frequency Maximum and
Minimum values fall outside the range of the Spectrum Frequency
Maximum, so that the band value is zero. When the speed is 1200 rpm, the
band is calculated from 150…200 Hz.

Speed
(rpm)

Max Frequency Represented in
Spectrum (Hz)

Band Min
(Hz)

Band Max
(Hz)

2400

400

150

250

1800

300

150

250

1200

200

150

200

600

100

N/A

N/A

Advertising