Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics. OR

• If you repair or replace any electrical components.

ENGINE RPM

Mode

No Load RPM

Load RPM

Low Idle

1400 - 1450

NA

High Idle

1890 - 1910

1750 - 1890

WELDER DC (STICK) OUTPUT

Mode Selector

Open Circuit

Switch

Fine Control

Voltage

Load Volts

Load Amps

30-575 Setting

Maximum

55 - 60

39.5 - 42.0

565 - 585

WELDER CV (WIRE) OUTPUT

Mode Selector

Open Circuit

Switch

Fine Control

Voltage

Load Volts

Load Amps

CV - Wire

Maximum

55 - 60

39 - 42

520 - 535

CV - Wire

Maximum

NA

48 - 49

20

CV - Wire

Minimum

55 - 60

13 - 14

20