Troubleshooting and repair, 0 volts 10v 5 µs, Normal tig mode voltage waveform – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 238

Advertising
background image

0 volts

10V

5 µs

This is the typical output voltage gen-
erated from a properly operating
machine in the TIG Mode.

Note that each vertical division repre-
sents 10 volts and that each horizontal
division represents 50 microseconds
in time.

The machine was loaded with a resis-
tance grid bank to 200 amps at 16
VDC.

SCOPE SETTINGS

Volts/Div.....................10V/Div.
Horizontal Sweep....05 ms/Div.
Coupling.............................DC
Trigger.........................Internal

NORMAL TIG MODE VOLTAGE WAVEFORM

LOADED TO 200A 16 VOLTS

TROUBLESHOOTING AND REPAIR

F-50

F-50

VANTAGE® 500

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising