Installation – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 10

Advertising
background image

INSTALLATION

A1.2

A1.2

VANTAGE® 500

TECHNICAL SPECIFICATIONS - Vantage 500® DEUTZ (K2271-1)

INPUT - DIESEL ENGINE

Make /Model

Description

Speed (RPM)

Displacement

Starting

Capacities

System

Deutz

3 cylinder

High Idle 1900

173 cu. in

12VDC battery

Fuel

F3L 912

44HP (33 kw)

(2.83L)

& Starter

(25 US gal

Diesel Engine

@ 1800 RPM

Full Load 1800

94.6L)

Code 10995

Bore x Stroke

Oil:

9.5 QTS.

3.94” x 4.72”

9.0L

(100mm x 120mm)

RATED OUTPUT @ 104°F(40°C) - WELDER

Duty Cycle

Welding Output

Volts at Rated Amps

100%

500 Amps (DC multi-purpose)

40 Volts

60%

550 Amps (DC multi-purpose)

36 volts

50%

575 Amps (DC multi-purpose)

35 volts

PHYSICAL DIMENSIONS

Height

(2)

Width

Depth

Weight

42.0 in

31.5 in.

63.1 in.

1615 lbs.

(1066.8 mm)

(800.1mm)

(1603mm)

(733kg)

(Approx)

1.

Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2.

Top of Enclosure. Add 6.6” (167.6mm) for exhaust.

OUTPUT @ 104°F(40°C) - WELDER AND GENERATOR

Welding Range

30 - 575 Amps CC/CV

20 - 250 Amps TIG

Open Circuit Voltage

60 Max OCV @ 1900 RPM

Auxiliary Power

(1)

120/240 VAC

12,000 WATTS, 60 Hz.

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising