Troubleshooting and repair, Stator voltage test (continued) – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation

Page 224

Advertising
background image

WELD WINDING

LEAD CONNECTIONS

W1

W6

W3

W2

W5

W4

FIGURE F.12 – OUTPUT RECTIFIER DIODE BRIDGE

STATOR VOLTAGE TEST (CONTINUED)

1. Locate the weld winding leads connected to the

three-phase output rectifier diode bridge. See
Figure F.12.

2. Check for approximately 68VAC from:

W1/W6 to W2/W3.

W1/W6 to W4/W5

W2/W3 to W4/W5

3. If any of these voltages are low or missing perform

the Flashing and Rotor Voltage Test and also the
Rotor Resistance Test.

4. Also check leads #6F and #5P for loose or faulty

connections to the field bridge. See the Wiring
Diagram.

5. If the tests in Steps 6 and 7 are OK and the stator

voltages are low or missing, the stator may be
faulty.

6. Replace the lower front panel and output leads.

7. Replace the upper control panel and secure.

8. Replace the front left and right case sides.

TROUBLESHOOTING AND REPAIR

F-36

F-36